{"product_id":"hks-super-sqv4-blow-off-valve-kit-for-08-10-wrx-05-06-legacy-2-5-gt","title":"HKS Super SQV4, Blow Off Valve Kit for 08-10 WRX  \/ 05-06 Legacy 2.5 GT","description":"\u003ch4\u003eSuper SQV4 Blow Off Valve\u003c\/h4\u003e\u003cp\u003eHKS Super SQV (Sequential Blow Off Valve) uses a unique sequential valve structure and a differential pressure control system, which allows for a broad operating range from low boost to high boost. Its Pull-Type relief design ensures stable operation regardless of the amount of boost pressure. The Super SQV will support new generations of turbocharged vehicles.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh Quality Aluminum Die-Cast Body - \u003c\/strong\u003eSilver-coated aluminum die-cast body. Combines the ultimate in looks and durability in the engine compartment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh\u003c\/strong\u003e \u003cstrong\u003eStiffness Metal Die-Cast Valve - \u003c\/strong\u003eSecondary valve main portion is made of die cast metal. Reliable operation with beautiful looking.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTriple Fin design produces \"Super Sound\" - \u003c\/strong\u003eTriple Fins set at the center of the funnel produces a dynamic and aggressive sound. An optional special Round Fin can be purchased separately for sound tuning.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePull-Type Relief Valve Operation - \u003c\/strong\u003eThe Pull-Type valve operation offers more precise relief of excess boost and is compatible for a wider range of boost pressure compared to typical push-type blow off valves.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePrimary Valve (Small) - \u003c\/strong\u003eLift off the throttle, and the primary valve instantly opens, quickly discharging initial excess boost pressure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSecondary Valve (Large) - \u003c\/strong\u003eThis valve combined with the Primary Valve from the sequential dual valve structure. Optimal blow-off operation from how to high boost ranges without leaking.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDual Valve Structure, Sequential System\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eAt low boost ranges the Primary Valve opens, and at high boost ranges the Secondary Valve also opens, resulting in linear response and optimal blow-off operation at all boost levels.\u003c\/p\u003e\u003cdiv style=\"margin-left: 6em\"\u003e\u003cdiv style=\"margin-left: 2em\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerator ON\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eValves Closed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.hks-power.co.jp\/en\/product\/blow_off\/sqv\/images\/img_04.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eAs pressure rises in chamber C, pressure is applied to both the Primary and Secondary valves. The higher the boost pressure, the more pressure is applied to the valves, preventing leaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerator OFF\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrimary Valve Opens\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.hks-power.co.jp\/en\/product\/blow_off\/sqv\/images\/img_05.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eThrottle lift creates a pressure difference between chambers A \u0026amp; B, opening the primary valve bypassing the secondary valve. this creates the initial discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerator OFF\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eSecondary Valve Opens\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.hks-power.co.jp\/en\/product\/blow_off\/sqv\/images\/img_06.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eWhen pressure difference in chambers A \u0026amp; B reach a maximum, the Primary Valve pulls the Secondary Valve open, creating a secondary discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePull-Type blow off valves will work for any turbocharged vehicle, from stock to highly tuned.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cp\u003eTypical push-type blow off valves require spring load settings for each vehicle specification. If the spring load setting is too low, the valve may leak under high boost and the desired boost setting may not be reach. If the spring load setting is too strong, it may not open at low boost. The Super SQV will operate under any boost pressure setting without leaking.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"https:\/\/www.hks-power.co.jp\/en\/product\/blow_off\/sqv\/images\/img_07.png\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSUPER SQV4 VEHICLE SPECIFIC KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eParts necessary for installation are included. SSQV4 can be easily installed on a vehicle with this kit.\u003c\/p\u003e\n\u003cp\u003eCirculation Adapter is Included.\u003c\/p\u003e\n\u003cp\u003eA triple fin and replacing type circulation adapter are included for a vehicle to install. (These parts are not included in the universal kit.) Using this recirculation adapter allows suction return by fabricating the return piping. (Some kits include Suction Return Kit.) The vehicle specific Suction Return Kit (Blow-off parts) is available separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"FR SPORT","offers":[{"title":"Default Title","offer_id":45481318645817,"sku":"0E08Q","price":434.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0762\/8632\/8889\/files\/9048565b76d21add7edc54a84e7d5d1e.png?v=1773687715","url":"https:\/\/shop.throttletherapynation.com\/products\/hks-super-sqv4-blow-off-valve-kit-for-08-10-wrx-05-06-legacy-2-5-gt","provider":"Throttle Therapy Nation ","version":"1.0","type":"link"}